1, electrical parameters: 1) CQC, VDE, UL, 50~60Hz 5A CULAC250V / 10A / 15A (resistive load) (2) AC 125V 50Hz 15A UL (resistive load) 2, the operating temperature range: 0~240 C (Ren Xuan), temperature accuracy: + 3 + 5 + 10 + 2 3, reply and action temperature difference: 8~100 C (Ren Xuan) 4, wiring way: insert terminal 250# (bending 0~90 degrees optional); insert terminal 187# (curved 0~90 degrees optional, thickness 0.5, 0.8mm optional) 5, the service life is more than 100000 times: 6, electrical strength: 50Hz 1800V AC lasted 1min, no flicker, no breakdown 7, contact resistance is less than or equal to 50m. 8, insulation resistance: less than 100M. 9, contact form: normally closed type: temperature rise, the contact is disconnected, the temperature drops, the contact is switched on; Normally open type: temperature rise, the contact is switched on, the temperature drops, the contact is broken. 10, shell protection grade: IP00 11, grounding way: through the temperature controller metal shell and the device connected to the metal parts. 12, installation way: KI-32 series installation ordinary activities ring, installation of the small ring, mounting plate ring, with mounting holes ordinary aluminum cover with ANN Mounting hole extended aluminum cover 13, the temperature range: -25 to +240 DEG +1 DEG C to 2 C
|